Monitor AMI Solicon 4

Monitor AMI Solicon 4

Specific (total) conductivity for surface water, cooling water and effluents

  • Selectable temperature compensation with absolute (none), linear coefficient or non-linear function
  • Insensitive to fouling due to 4-electrodes principle. No measuring errors due to polarization effects
  • Measurement of concentrations (for NaCl, NaOH and acids in %), salinity and TDS possible
  • Optional deltaT sensor for flow detection

Specifications

Measuring of specific conductivity, TDS or salinity

Conductivity measurement with Swansensor Shurecon P including Pt1000 temperature sensor
Measuring range 0.10 µS/cm to 100 mS/cm
Resolution see datasheet
Accuracy +- 0.5% of measured value
Temperature measurement (Pt1000)
Measuring range -30 to 130°C
Resolution 0.1° C
Power Supply
Voltage 100-240 VAC (±10%), 50/60Hz
or
10-36 VDC
Sample conditions
Flow rate 4 to 15 l/h
Temperature up to 50° C
Inlet pressure up to 1 bar
Outlet pressure pressure free
Dimensions
Panel 280 x 850 x 150 mm