Monitor AMI-II Fluotrace Oil

Monitor AMI-II Fluotrace Oil

Sensitive online analyser for continuous detection of oil and polycyclic aromatic hydrocarbons in water.

The AMI-II Fluotrace Oil is a precision fluorescence analyser designed for continuous measurement of oil and polycyclic aromatic hydrocarbons (PAH) in water. Its UV fluorescence technology detects very low levels of hydrocarbon contamination, with a typical response time of under six seconds. Suitable for pure and potable water, cooling water, return condensate, surface water, seawater treatment and effluent applications, the low-maintenance system delivers dependable real-time monitoring to support water quality management and early identification of oil contamination.

Key Features

  • Continuous, high-sensitivity UV fluorescence monitoring of oil and polycyclic aromatic hydrocarbons in water.
  • Detects very low contamination levels, with a typical detection limit of 0.15 ppm for oil or 5 ppb for PAH.
  • Response time of under six seconds supports rapid identification of hydrocarbon contamination.
  • Long-life LED technology maintains stable performance without routine replacement of the light source.
  • Durable titanium sensor shaft is suitable for a wide range of water monitoring applications.
  • Supports manual verification using precise reference standards.
  • Low-maintenance, panel-mounted system supplied ready for installation and operation.

 

 

AMI-II Fluotrace Oil Specifications

The AMI-II Fluotrace Oil is a precision online fluorometer designed for continuous measurement of oil and polycyclic aromatic hydrocarbons in water.

Using UV fluorescence, the analyser excites the sample at 255 nm and measures the resulting fluorescence at 360 nm. Applications include pure and potable water, cooling water, return condensate, surface water, seawater treatment and effluent monitoring.

The complete analyser is supplied on a PVC panel, factory-tested and ready for straightforward installation and operation.

 

Fluorescence measurement

Measurement principle UV fluorescence
Excitation wavelength 255 nm
Detection wavelength 360 nm
Accuracy ±10% of the measured value + 5 ppb
Response time Less than 6 seconds (t90)

PAH measurement

Measuring range 0.00 to 9.99 ppb
Resolution 0.01 ppb
Measuring range 10.0 to 999.9 ppb
Resolution 0.1 ppb
Measuring range 1000 to 5000 ppb
Resolution 1 ppb
Limit of detection 5 ppb PAH

Oil measurement

Measuring range 0.00 to 9.99 ppm
Resolution 0.01 ppm
Measuring range 10.0 to 150.0 ppm
Resolution 0.1 ppm
Typical limit of detection 0.15 ppm oil

Sample conditions

Flow rate Approximately 5 to 50 L/h
Temperature Up to 40 °C
Inlet pressure at 25 °C Up to 1 bar
Outlet pressure Pressure-free

Power supply

AC version 100–240 VAC (±10%), 50/60 Hz (±5%)
DC version 10–36 VDC
Power consumption Maximum 35 VA

Panel

Dimensions 280 × 850 × 200 mm
Material White PVC
Total weight 7.7 kg

 

Contact us to place an order.

Downloads

Brochure Product Flyer
Datasheet Datasheet