AMI-II Turbisafe is a cost-effective online analyser for continuous turbidity monitoring in accordance with ISO 7027.
The AMI-II Turbisafe provides dependable turbidity measurement across a wide range from 0.000 to 100 FNU/NTU. Delivered fully tested, calibrated and ready for installation, the analyser incorporates a robust flow cell designed to withstand inlet pressures of up to 10 bar, reducing the risk of measurement errors caused by sample degassing.
No desiccant bags, cuvettes or other consumables are required, and both the flow cell and sensor head can be cleaned quickly to simplify ongoing maintenance. Measurements may be checked or calibrated using a primary formazine standard. Available options include a second turbidity sensor, sample flow measurement or control, and an automatic cleaning module.
Key Features
- Continuous turbidity monitoring compliant with ISO 7027.
- Wide measurement range covering 0.000 to 100 FNU/NTU.
- Robust flow cell withstands inlet pressures up to 10 bar, reducing errors associated with sample degassing.
- Operates without desiccant bags, cuvettes or other ongoing consumables.
- Sensor head and flow cell are easy to clean for simplified maintenance.
- Results can be checked or calibrated using a primary formazine standard.
- Optional configurations include a second turbidity sensor, sample flow measurement or control, and automatic cleaning.
AMI-II Turbisafe Specifications
The AMI-II Turbisafe is a complete online analyser designed for continuous turbidity monitoring in accordance with ISO 7027. Each system is supplied fully tested, calibrated and ready for installation and operation.
Its durable flow cell can accommodate inlet pressures of up to 10 bar, helping minimise inaccurate readings caused by sample degassing. With no desiccant bags, cuvettes or other consumables required, the analyser supports low ongoing operating and maintenance costs.
Available options include a second turbidity sensor for measurements before and after filtration, a sample flow meter or flow controller, and an automatic cleaning module.
Turbidity measurement
| Measurement principle | Nephelometric measurement in accordance with ISO 7027 |
| Measuring range | 0.000 to 100 FNU/NTU |
| Precision | ±0.02 FNU (limit of detection) |
| Calibration standard | Primary formazine standard |
Measurement accuracy
| 0 to 1 FNU | ±0.01 FNU or ±2% |
| 1 to 10 FNU | ±0.1 FNU or ±3% |
| 10 to 100 FNU | ±0.5 FNU or ±5% |
Sample conditions
| Flow rate | Approximately 5 to 50 L/h |
| Sample temperature | Up to 40 °C |
| Inlet pressure | Up to 10 bar |
| Outlet pressure | Pressure-free |
Power supply
| AC version | 100–240 VAC (±10%), 50/60 Hz (±5%) |
Contact us to place an order.